538 Appendix A Command Reference
STRG
STRetchinG SCL Low Signal
Class EDID and DDC control
Description Enables a stretching capability for the receiver of the HDMI analyzer. Each time a host
accesses the I2C receiver bus (for example, to read the EDID), the receiver stretches the
SCL low signal for 5 ms.
Enable stretching for testing purposes only.
Command syntax STRG value
value
0 = deactivate stretching
1 = activate stretching of SCL low signal for 5 ms
Query syntax STRG?
Query response 0 or 1
Example
STRG 1
DIDU
Related commands DIDU