Video Test Generator User Guide 489
PSPP
Probe Sync Pulse Polarity
Class Special Sync Probe Pulse
Description Sets the polarity of the probe pulse on the special sync output. The PSPG? query returns
the current PSPP value.
Command syntax PSPP polarity
polarity integer
0 = negative
1 = positive
Query syntax PSPP?
Query response 0 or 1
Other required
commands
The FMTU command instructs the generator to use the new settings. The ALLU command
updates the hardware to the new settings and redraws the test image.
Related commands PSPG, PSPW, PSHD, PSVD, PSPM
Example
PSPG 1 // Enables probe pulse on special sync
PSPP 1 // Sets probe pulse polarity to positive
ALLU // Applies the settings