Vue de la page 210
802BT/802R Video Test Generator User Guide 201
Configuring special sync for FS, LS or CS
The special sync output can provide frame sync, line sync, or composite sync signals. The
output is controlled by setting parameters of these signals through the command line
interface. The following commands are used to set the special sync signal:
FSPG
- Frame sync
PSPG
- Probe signal
LSPG
- Line sync
CSPG
- Composite sync
Note: The special sync output is disabled whenever these parameters are set to zero.
A frame pulse can be generated and output at the beginning of each frame. In the case of
interlaced video, the frame pulse is output at the beginning of the blanking interval (of the
first field) that immediately precedes the top line of active video.
To configure frame sync on the special sync output:
1. Enable the frame sync by entering the following command:
FSPG 1
The values of the other parameters (
LSPG and CSPG
) do not matter once FSPG is
enabled.
2. Set the frame pulse polarity (either 0 for low or 1 for high) by entering the following
command:
FSPP 1
FSPG=1, FSPP=0
FSPG=1, FSPP=1
FSPW (pixels)
FSPD (lines)
ActiveBlank Blank Active
Field 0 Field 1
VSPD (lines)
VID
VS
FS
FS
Vue de la page 210