Vue de la page 268
Video Test Generator User Guide 259
CSPG
Composite Sync Pulse Gate
Class Format parameter setting - Synchronization
Description Enables and disables all of the digital composite sync outputs when digital composite sync
is selected via the SSST command (SSST = 3). The CSPG? query returns the current
setting of CSPG.
Command syntax CSPG mode
mode
0 = OFF
1 = ON
Query syntax CSPG?
Query response 0 or 1
Other required
commands
In order to use digital composite sync, it must be selected with the SSST command. The
FMTU command instructs the generator to use the new setting. The ALLU command
updates hardware to the new setting and redraws the test image.
Example
CSPG 1 // Enable dig comp sync in buffer
SSST 2 // Choose digital comp sync type in buffer
FMTU // Update hardware to current buffer contents