Quantum Data 802R Guide de l'utilisateur Page 393

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 744
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 392
Video Test Generator User Guide 383
IDET
Initialization DETect
Class System Parameter
Description Stores the integer flag value in non-volatile memory. The value is not changed except by
1) another IDET command, 2) re-initializing the unit with an INIT command, or 3) the
system firmware because the power-up self test found corrupted data in battery backed
system memory. In cases 2 and 3, the IDET value will revert to 0. The IDET? query returns
the current IDET value. The IDET command and query are used by automated test
systems to determine if a particular unit has been replaced or reinitialized since it had its
IDET value set to unique number by that system.
Command syntax IDET integer flagNeed help with this syntax and parameter formatting.
-2,147,483,647 ??integer flag?? +2,147,483,647
Query syntax IDET?
Query response flag
Example
IDET 19980616 // Set IDET to a non-zero value