8-7
Format Error Messages
2030 SCAN less than 1
An invalid scan setting exists in the file.
Reedit the scan setting.
2040 SCAN greater than 2
An invalid scan setting exists in the file.
Reedit the scan setting.
2050 Horizontal total too small
The generator does not support a horizontal period (active
+ blanked) less than 144 pixels per horizontal scan line.
Increase the horizontal period so that it’s more than
143 pixels.
2060 Horizontal total too large
The generator does not support a horizontal period (active
+ blanked) of more than 4096 pixels per horizontal scan
line.
Decrease the horizontal period so that it’s less than
4096 pixels.
2071 Pixel rate too high
The pixel rate exceeds the maximum rate supported by the
currently selected generator model for the given video type
selection.
Make sure video type is correct.
Decrease the pixel rate.
Decrease the horizontal period (in pixels) for a given
horizontal rate.
2072 Pixel rate too high
The pixel rate exceeds the maximum rate supported by the
currently selected generator model for the given video type
selection.
Make sure video type is correct.
Decrease the pixel rate.
Decrease the horizontal period (in pixels) for a given
horizontal rate.